Software Version 12.0.2
You can use a computer that functions in the same subnet as the switch to
access the web management interface over the switch’s default IP address and
assign another static IP address to the switch.
To set up the switch IP address configuration through the web management interface:
1. Prepare your computer with a static IP address:
For access over an Ethernet network port, use a static IP address in the 169.254.0.0/16 subnet.
For example, use 169.254.100.201 for your computer.
For access over the OOB port, use a static IP address in the 192.168.0.0/16 subnet.
For example, use 192.168.0.201 for your computer.
2. Connect an Ethernet cable from an Ethernet port on your computer either to an Ethernet network port on the switch or to the OOB port on the switch.
3. Launch a web browser such as Google Chrome, Mozilla Firefox, or Microsoft Internet Explorer.
4. Enter the default IP address of the switch in the web browser address field:
• For access over an Ethernet network port, enter 169.254.100.100.
• For access over the OOB port, enter 192.168.0.239.
The login window opens.
M4300 OOB Port